| Distillation Method | Vacuum Potential (mm Hg) | AEBP Potential | Comment |
| Batch w/Condenser | 50 | 465°C
870°F |
Long holding period (at OBP)
Single tray |
| Fractional Column | 20 | 500°C
933°F |
Low AEBP
Multiple trays possible Good separation |
| Packed Column | 20 | 500°C
933°F |
Low AEBP
Single tray device Good separation |
| Wiped Film Evaporator | 1 | 585°C
1085°F |
Medium AEBP
External Condenser Single tray device |
| Short Path Evaporator | 0.001 | 740°C
1365°F |
Very High AEBP
Internal Condenser Single tray device |